Shape | Square type |
---|
Sensing method | Distance-setting |
---|
Sensing distance | White paper 100 x 100 mm: 20 to 300 mm Black paper 100 x 100 mm: 20 to 160 mm |
---|
Setting range | White paper 100 x 100 mm: 40 to 300 mm Black paper 100 x 100 mm: 40 to 160 mm |
---|
Spot size | 0.5 mm dia. max. (sensing distance: 300 mm) |
---|
Minimum sensing object | 0.2 mm min. dia. (Pin gauge (Stainless steel) at 300 mm) |
---|
Differential distance | 5% max. of setting distance |
---|
Reflectivity characteristic (black-white error) | 5% max. at setting distance 160 mm |
---|
Light source | Red LD (655 nm) |
---|
Classification of laser | IEC: Class 1 FDA: Class 1 JIS: Class 1 |
---|
Power supply voltage | 12 to 24 VDC±10% ripple (p-p) 10% max. |
---|
Current consumption | 30 mA max. |
---|
Control output | NPN open collector 26.4 VDC max. 100 mA max. Residual voltage: 1 V max. (Load current Less than 10 mA) Residual voltage: 2 V max. (Load current 10 to 100 mA) |
---|
Operation mode | Light-ON/Dark-ON selectable |
---|
Protective circuit | Output short-cut protection, Output reverse polarity protection, Power supply reverse polarity protection |
---|
Response time | Operate or reset: 1 ms max. |
---|
Sensitivity setting | 5-turn endless adjustment |
---|
Ambient illuminance | Incandescent lamp: 3,000 lx max. Sunlight: 10,000 lx max. |
---|
Ambient temperature range (Operating) | -10 to 55 ℃ (with no freezing or condensation) |
---|
Ambient temperature range (Storage) | -25 to 70 ℃ (with no freezing or condensation) |
---|
Ambient humidity range (Operating) | 35 to 85 % (with no freezing or condensation) |
---|
Ambient humidity range (Strage) | 35 to 95 % (with no freezing or condensation) |
---|
Insulation resistance | 20 MΩ min. (500 VDC megger) |
---|
Dielectric strength | 1000 VAC 50/60 Hz 1 min |
---|
Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude each in X, Y, and Z directions for 2 h |
---|
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y and Z directions |
---|
Degree of protection | IEC: IP67 |
---|
Connection method | Pre-wired models (Cable length 0.5 m) |
---|
Indicator | Operation indicator (orange), Stability indicator (green) |
---|
Accessories | Instruction manual |
---|
Material | Case: Polybutylene terephthalate (PBT) Lens: Denatured Polyarylate |
---|